DLT 100 2.0 Digital Transceiver and DLR 60 2.0 Digital Receiver
18
2-Way Setup for Tour Guide Operation (continued)
Address ( ADD ) icon will
now begin to blink. Use
the
buttons to
select a Address number (
0 – 1023 ).
Note: Attendee count will
only work with addresses
1-99 (Maximum 100 DLT
100 2.0’s with one Master at
address 0).
Press
button to enter
Address number and move
to the next setting.
GROUP icon will now
blink. Use the
buttons to select a Group
number. Must have one
Master in a group; and the
MAS and SLV units must
have same group number.
Press button to
enter Group number and
move to the next setting.
For 4 simultaneous
groups, numbers must be
consecutive. ie ( 11, 12, 13,
14 ). Can use (0 - 1023) for
group numbers.
The secure code screen
will now be displayed, with
the rst character blinking.
Use the
buttons
to select the rst number (
0 – 9).
Press button to
advance to the next position.
Repeat steps 17 and 18
until all numbers have been
entered. When the last
number has been entered,
nothing will be blinking.
Press
button to save
the secure keycode. You
are now at the beginning
of the programming. Press
and together
for 3 seconds to exit
programming mode and
return to the main screen.
If this is a slave unit, the
side-tone adjustment will be
displayed (not avail on CM
or CS). Use the
buttons to select a side-
tone level ( 0 – 2 ).
Press button to save
side-tone level and move to
the next setting.
If this is a slave unit,
the Push-to-talk/Push-
and-latch feature will
be displayed (not avail
on CM or CS). Use the
buttons to
select Ptt or PnL.
Press button to save
the Ptt or PnL setting and
move to the next setting.